Most ebook files are in PDF format, so you can easily read them using various software such as Foxit Reader or directly on the Google Chrome browser.
Some ebook files are released by publishers in other formats such as .awz, .mobi, .epub, .fb2, etc. You may need to install specific software to read these formats on mobile/PC, such as Calibre.
Please read the tutorial at this link: https://ebookbell.com/faq
We offer FREE conversion to the popular formats you request; however, this may take some time. Therefore, right after payment, please email us, and we will try to provide the service as quickly as possible.
For some exceptional file formats or broken links (if any), please refrain from opening any disputes. Instead, email us first, and we will try to assist within a maximum of 6 hours.
EbookBell Team
0.0
0 reviewsCathodic protection of steel in concrete
1 Scope
This document specifies performance requirements for cathodic protection of steel in cement-based
concrete, in both new and existing structures. It covers building and civil engineering structures,
including carbon steel reinforcement and prestressed reinforcement embedded in the concrete. It is
applicable to uncoated steel reinforcement and to organic-coated steel reinforcement. It is not applicable
to reinforced concrete containing electrically conductive fibres (e.g. carbon or steel).
This document applies to steel embedded in atmospherically exposed, buried, immersed and tidal
elements of buildings or structures.
This document is only applicable to the applications of cathodic protection to steel in concrete which
are designed with the intention to, and can be demonstrated to, meet the criteria of protection specified
in 8.6. This requires the provision of sufficient performance monitoring systems as specified in 6.3 to
all parts of the structure intended to be protected, in order to assess the extent to which the criteria in
8.6 are met.
This document does not apply to galvanic anodes or systems applied into patch repairs to reduce the
effects of ‘incipient anodes’. This document does also not apply to any form of cathodic protection
systems or other electrochemical treatments that either cannot meet the requirements of 8.6 or are not
provided with the performance monitoring systems (see 6.3) that are necessary to assess whether the
criteria of protection specified in 8.6 are met.
NOTE 1 Annex A gives guidance on the principles of cathodic protection and its application to steel in concrete.
NOTE 2 This document, while not specifically intended to address cathodic protection of steel in any
electrolyte except concrete, can be applied to cathodic protection of steel in other cementitious materials such as
are found, for example, in early 20 th century steel-framed masonry, brick and terracotta clad buildings. In such
applications, additional considerations specific to these structures are required in respect of design, materials
and installation of cathodic protection; however, the requirements of this document can be applied to these
systems.